Vaginitis Panel

Overview

  • EPIC Code:
  • LAB2548
  • Soft Test Code:
  • VAGP2
Alternate Names
  • Bacterial Vag Panel
  • BD Max Vag Panel
  • Vag Panel
  • Vaginitis Panel PCR
Included Tests

Bacterial Vaginosis; Candida spp; Candida glabrata; Candida krusei; Trichomonas vaginalis


Specimen Collection & Preparation

Specimen Overview

The BD Molecular Swab Collection Kit contains one sterile polyester-tipped vaginal collection swab and a Sample Buffer Tube (SBT) contaning 2.0 mL of potassium phosphate, EDTA, Tween 20, adn Procilin presevatives. 

Specimen Requirements:

-OR-

1 Vaginal Swab placed in the Sample Buffer Tube (SBT)
Specimen Information:


Collection Instructions:

No lubricants may be used before/during collection of this test.

Provider collection instructions

Patient in-house collection instructions to be completed at Parkview facility

Swabs are not to be sent home with patients.


Rejection Criteria:

Any swab used other than that in the BD Molecular Swab Sample Buffer kit. Any buffer tube (green cap) received without the correct swab inserted and broken off. Any buffer tube received with a punctured foil top. Any buffer tube received without the liquid buffer. 


Transport and Storage:
  • Ambient: 21 Days

    Properly collected sample

  • Ambient: 4 Days

    Samples that have a punctured cap may be stored upright if originally punctured within the 21 day stability.

Clinical Interpretation

Reference Range:

Not Detected


Test Comments:

Bacterial vaginosis result is calculated using an algorithm. Several individual markers and organism profiles are taken into account by this algorithm.


Methodology:
  • Polymerase Chain Reaction (PCR)

Production Schedule

Sites Performed
  • Parkview Regional Medical Center
Days Performed
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Departments
  • Microbiology
Turn Around Time

8 hours / Same Day


Coding & Compliance

CPT Coding

81514