Respiratory Pathogen Panel with CoVid

Last Modified: 7/6/2023 4:02:49 PM


Medical Necessity Documentation:  
Client Notes:  
Patient Preparation:  
Specimen Requirements:  XPERT Nasopharyngeal Swab Specimen Collection Kit (Red Top / Pink Fluid)
Collection Instructions:  Nasopharyngeal Collection 
Minimum Volume: 300 uL
Transport & Storage: Temperature/Stability: 4 hours Ambient
3 days Refrigerated
30 days Frozen
Rejection Criteria: Swabs received in saline
Reference Range: No respiratory pathogens detected by BioFire PCR
Critical Ranges:  
Test Comments: Specimens are tested for Adenovirus, Coronavirus (HKU1, NL63, 229E, OC43, and SARS-CoV2 (COVID-19)), human Metapneumovirus, human Rhinovirus/Enterovirus, Influenza (A, A/H1, A/H1-2009, A/H3, B), Parainfluenza (1, 2, 3 and 4), Respiratory Syncytial Virus (RSV), Bordetella pertussis, Bordetella parapertussis, Chlamydophila pneumoniae, and Mycoplasma pneumoiae
Methodology: Multiplex PCR
Clinical Significance: Detection of 15 viruses and 4 bacterial pathogens from Nasopharengeal Swab (NPS).
Documentation:  
Custom Panel: No

PRODUCTION SCHEDULE

Turn Around Time: 8 hours
Days Performed: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday
Sites Performed: Parkview Regional Medical Center
PHL Test Code: RVPLC
EPIC Test Code: LAB3213
Alternate Test Names: Respiratory Panel by PCR; Respiratory Panel on BioFire; RP Panel w/ Covid
Included Tests: Adenovirus; Bordetella pertussis; Chlamydophila pneumoniae; Coronavirus 229E; Coronavirus HKU1; Coronavirus NL63; Coronavirus OC43; Human Metapneumovirus; Human Rhinovirus/Enterovirus; Influenza A (A, A/H1, A/H1-2009, A/H); Influenza B; Mycoplasma pneumoniae; Parainfluenza Virus (1-4); Respiratory Syncycial Virus; SARS-CoV-2 (COVID-19)
CPT Coding: 0202U

Go back to the top of the page.