Type and Screen, Automated

Last Modified: 6/8/2023 10:42:14 AM


Medical Necessity Documentation:  
Client Notes:  
Patient Preparation:  
Specimen Requirements: 6.0 mL Whole Blood in a Pink Top Tube - EDTA
Collection Instructions:

Specimen should be labeled with the patient's name, date and time of collection, [date of birth and/or social security number] and the phlebotomist's (collector's) initials

Do not collect in a Serum Separator Tube (SST or PST)

Do not open Red Top Tube

Minimum Volume: 3.0 mL Whole Blood EDTA
Transport & Storage: Temperature/Stability: 24 hours Ambient 
72 hours Refrigerated

This Blood Bank test should be performed within 72 hours. If longer than 72 hours patient should be redrawn.
Reference Range: Antibody Screen: Negative
ABO/RH: Not Applicable
Critical Ranges:  
Test Comments:  
Methodology: SPRCA
Clinical Significance:  
Documentation: Methodology for Antibody Screen: Solid Phase Red Cell Adherance
Methodology for ABO/RH: Hemagglutination
Custom Panel: No

PRODUCTION SCHEDULE

Stat Eligible: Yes
Days Performed: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, Saturday
Sites Performed: Parkview Dekalb Hospital, Parkview Huntington Hospital, Parkview LaGrange Hospital, Parkview Noble Hospital, Parkview Randallia Hospital, Parkview Regional Medical Center, Parkview Wabash Hospital, Parkview Whitley Hospital
PHL Test Code: GRPSC
EPIC Test Code: LAB276
Alternate Test Names: Group Screen; T & S
Included Tests:

ABO; Antibody Screen; RH

CPT Coding: 86850, 86900, 86901 (Reflexes 86870)

Go back to the top of the page.