Lymphogranuloma Venereum Antibodies Panel

Last Modified: 9/1/2017 12:52:55 PM


Specimen Requirements: 1.0 mL Serum in a SST Gold Top Tube
Minimum Volume: 0.4 mL Serum
Transport & Storage: Temperature/Stability: 48 hours Ambient
7 days Refrigerated
2 months Frozen
Reference Range:
Chlamydia pneumoniae IgG Antibodies:  <1:16 titer 
Chlamydia pneumoniae IgM Antibodies: < 1:10 titer 
Chlamydia pneumoniae IgA Antibodies: <1:16 titer 
Chlamydia trachomatis IgG Antibodies: <1:64 titer 
Chlamydia trachomatis IgM Antibodies: <1:10 titer 
Chlamydia trachomatis IgA Antibodies: <1:16 titer 
Methodology: Micro-Immunofluorescence
Custom Panel: No

PRODUCTION SCHEDULE

Turn Around Time: 2 to 3 days
Days Performed: Tuesday, Wednesday, Thursday, Friday
Sites Performed: Quest - Chantilly to Valencia
PHL Test Code: MSOT
EPIC Test Code:
Send Out Test Code: 8061
Alternate Test Names: LGV; Lymphogranuloma Venereum Abs; MIF Titer
Included Tests: Chlamydia pneumoniae IgA Antibodies; Chlamydia pneumoniae IgG Antibodies; Chlamydia pneumoniae IgM Antibodies; Chlamydia trachomatis IgA Antibodies; Chlamydia trachomatis IgG Antibodies; Chlamydia trachomatis IgM Antibodies
CPT Coding: 86631 x 4, 86632 x 2

Go back to the top of the page.